11-13-2007 - Porter (Higher Spirits)SP-0719 — PORTER (HIGHER SPIRITS)
SITE PLAN SUBMTITAL DATE: 9/26/07
TRC DATE: 11/13/07
MINUTES
IN ATTENDANCE:
DARREN LEAR, DEV. SVS. DIR.
JILL DANIGEL, FIRE MARSHAL
TERRY WADSWORTH, ENV. SVS. DIR.
GRANT RENNE, EPI
STEPHANIE PORTER, OWNER
MATT PORTER, OWNER
PAT DROSTEN, PLANNING TECH
All sections referenced are from the City of Edgewater Land Development
Code (LDC)
Planning Dept
1. Show driveway distance from property line, adjacent driveways and
closest intersection.
OKAS IS
2. Show stormwater flow and outfall to public conveyance on Site Plan.
WILL INDICATE
3. Section 21 requires a 24' aisle width and a 15' maneuver depth and
radius for all parking spaces.
WILL INDICATE
4. Indicate size of existing building on Site Plan.
WILL INDICATE
5. A total of 9 trees are required and only 8 are shown on the Site Plan.
WILL INDICATE
6. Landscape Plan must include the language listed in Section 21-54.02 of
the LDC. `All plant materials used in conformance with the
requirements of this Section shall be Florida grade #1, as established,
and periodically revised by the Florida Department ofAgriculture and
Consumer Affairs. "
WILL INDICATE
7. Please indicate that all disturbed areas are to be sodded.
WILL INDICATE
8. Per Section 21.54.03(b), wheel stops are not permitted.
WILL INDICATE
9. Staff recommends an additional parking space for future use /expansion.
NOTED
10. Indicate proposed use of existing driveway on 26th Street.
WILL INDICATE
11. A Class C landscape buffer is required abutting the north and east
property lines, per Section 21 -54.04 (Table V-5).
WILL INDICATE
12. Show irrigation plans.
WILL ADDRESS
13. Show placement of proposed wall on Site Plan.
WILL INDICATE
14. Indicate on Landscape plan that minimum tree protection standards will
be met, per Section 21.55.07.
WILL INDICA TE
15. Indicate proposed signage.
WILL INDICATE
Building Dept
1. Interior plans were not submitted for review. Due to the operation that is
proposed, there may be a fire separation requirement due to the close
proximity of residential use (less than 20 feet to the north).
WILL INDICATE THAT BLDG WILL BE SPRINKLED
Environmental Services
1. The location of the nearest hydrant is at 26th and Guava, but should be
indicated on the plans.
WILL INDICATE
2. The water and sewer service to the site exists, but the sewer lateral
location should be shown on the plans as well as the location and type of
the backflow prevention device.
WILL INDICATE
3. The use of wheel stops is permitted only when certain stormwater
conditions warrant their use.
WILL REVISE
4. A topographic survey showing the proposed infrastructure with elevations
of such including the swale area, edge of roadway, driveway and
stormwater pond should be provided.
WILL DISCUSS WITH DAVID KING
5. An outfall to a public stormwater conveyance system should be provided,
in this case to the swale along Guava Drive.
WILL DISCUSS WITH DAVID KING
6. Removal of the existing concrete driveway and the 12" CPP along with
reshaping of the swale is recommended.
WILL ADDRESS PROPOSED USAGE OF DRIVE WA Y
7. An Erosion and Sediment Control Plan for the contractor is required that
includes at a minimum silt fencing, and a dumpster or other container
adequately sized to contain all debris during construction. Other
measures may be required during construction.
TERRY WILL CHECK ON THIS ITEM
8. A note needs to be added on the plans stating all disturbed areas shall be
sodded.
WILL ADDRESS
Engineer
1. The plans should include a note stating "All construction shall in
conformance with the City of Edgewater Land Development Code and
Standard Construction Details, Latest Version, unless otherwise
specifically approved.
WILL INDICATE
2. Topographic information should be provided showing contour lines at
swales and ditches, elevation marks at driveway, street edges and
doorways to allow for confirmation of elevation restrictions /requirements
compliance and stormwater adequate drainage.
WILL DISCUSS WITH DAVID KING
3. A culvert may be necessary along Guava Drive R/W for access driveway.
WILL DISCUSS WITH DAVID KING
4. An out-fall weir to public stormwater system should be provided for the
retention pond
WILL DISCUSS WITH DAVID KING
5. Applicant to clarify Pervious /Impervious areas tabulation and
Stormwater calculations including existing building and pavement.
WILL DISCUSS WITH DAVID KING
6. The roof drainage should be routed to the stormwater treatment system.
WILL DISCUSS WITH DAVID KING
7. All disturbed pervious areas should be sodded and pertinent notes added
to site plan.
WILL INDICA TE
8. Nearest fire hydrant location should be shown on plans.
WILL INDICATE
9. Two -way access driveway should be 24' wide.
OKAS IS
10. A pave driveway connection to 26th Street should be provided.
WILL ADDRESS PROPOSED USAGE OF DRIVE WA Y
Fire Dept
1. All applicable fire and life safety standards must be met prior to issuance
of an occupational license /certificate of occupancy.
NOTED
2. The required fire flow for this project is 1500 GPM.
NOTED
3. Indicate on plan the location of nearest fire hydrant
NOTED
These comments are intended to comply with City of Edgewater Land
Development regulations, FDOT standard specifications and sound
engineering practices, and are not meant to be inclusive of all errors or
omissions. The engineer of record is solely responsible for technical accuracy,
engineering judgment, and quality of work.
While every effort is made to assure that projects reviewed by this office
comply with all applicable codes and standards, we do not certify or
guarantee that they do. It is the responsibility of the applicant to assure
compliance with all applicable codes and standards prior to the project being
issued a certificate of occupancy.