11-13-2007 - Geil/Kolodzik - Guava DriveSP-0720 — GEIL/KOLODZIK - GUAVA DR
SITE PLAN SUBMITTAL DATE 10/9/07
TRC Date 11/13/07
MINUTES
IN ATTENDANCE:
DARREN LEAR, DEV. SVS. DIR.
JILL DANIGEL, FIRE MARSHAL
TERRY WADSWORTH, ENV. SVS. DIR.
LUIS GEIL
PAT DROSTEN, PLANNING TECH
All sections referenced are from the City of Edgewater Land Development
Code
Planning Dept
1. Show driveway distance from property line and adjacent driveways.
WILL SHO W
2. Indicate proposed use of area east of the southern parking stalls. Staff
recommends area be striped as a "no parking" zone.
WILL SHO W
3. Indicate that the Section 21 — Area Tree Protection Requirements
have been met.
WILL SHO W
4. Show irrigation plan.
OKAS IS
5. Remove "banks" from General Note #4 and replace with "All disturbed
areas are to be sodded ".
WILL SHO W
6. Indicate any proposed signage.
NONE PROPOSED
7. The proposed plan indicates an area for outdoor storage. Please note that
outdoor storage requires a conditional use permit, which must be granted
by the Planning and Zoning Board.
WILL REVISE
8. The following documents are required:
• 25 Ownership and Encumbrance Report (O &E) dated less than
six (6) months or a Title Insurance Policy dated less than six (6)
months or a Title Report dated less than six (6) months, from a Title
Company, including Warranty Deed and all referenced documents;
(Submitted documents are dated July 2006);
WILL SUBMIT
• Application for Commercial Water/Wastewater Service; and
WILL SUBMIT
• Completed Stormwater Permit Application.
WILL SUBMIT
Building Dept
Construction plans must be sealed by an engineer to the FBC 2004 with the
2006 revisions and NEC 2005
NOTED
Environmental Services
1. Please ensure the City of Edgewater Standard Construction Details are
applied where applicable to the construction of this project. I do not
believe the refuse enclosure shown on the plans is consistent with Detail
Reference M-13 of the Standard Construction Details.
OKAS IS
2. Please add a construction note stating that a dumpster or other container
sufficient enough to contain all waste will be provided during
construction.
WILL REVISE
3. It is recommended to relocate the Laurel Oaks on the landscape plans as
they are very close to the exfiltration system and root system could cause
problems in the future.
WILL REVISE
4. The culvert under the driveway needs to be either RCP or smooth interior
plastic piping.
WILL REVISE
5. The outfall from the retention pond needs to be directed towards Guava
Drive. No direct discharge to the canal is allowed.
WILL REVISE
Legal Dep
Title work is insufficient for review.
WILL SUBMIT
Engineer
1. The plans should include a note stating, "All construction shall in
conformance with the City of Edgewater Land Development Code and
Standard Construction Details, Latest Version, unless otherwise
specifically approved.
WILL REVISE
2. All disturbed pervious areas should be sodded and pertinent notes added
to site plan.
WILL REVISE
3. Applicant should justify use of exfiltration system as such is to be
discouraged per Section 21.53.04(h).
WILL REVISE
4. Proposed overflow weir should be connected to drainage ditch with formal
pipe or other method to prevent erosion.
WILL REVISE
5. A City-FDOT standard stop bar and stop sign should be provide at access
driveway.
WILL REVISE
Fire Dept
1. The required fire flow for this project is 1500 GPM.
WILL REVISE
2. Indicate on plan the location of nearest fire hydrant.
OK AS IS
These comments are intended to comply with City of Edgewater Land Development
regulations, FDOT standard specifications and sound engineering practices, and are
not meant to be inclusive of all errors or omissions. The engineer of record is solely
responsible for technical accuracy, engineering judgment, and quality of work.
While every effort is made to assure that projects reviewed by this office comply with
all applicable codes and standards, we do not certify or guarantee that they do. It is
the responsibility of the applicant to assure compliance with all applicable codes and
standards prior to the project being issued a certificate of occupancy.