09-25-2001 - Mad HatterMAD HATTER COMMENTS TRC MEETING 9/25/01 Planning Department General • A St. John's permit will be required for the total impervious surface area or the square footage of the parking lot should be reduced for a City Stormwater permit. Will try to reduce impervious surface. • The Site Plan should have two phases to accommodate future development, otherwise, another site plan will be required for the future addition. Will resubmit for future additions. • If the project is not divided into two phases, add a note to the site plan stating that the future addition will not be a part of the 1 S ` submittal. Will show. • Revise notes on Sheet 1 to reflect the square footage of the initial building. Will show. Fix note on Sheet 2 to FEMA Zone "X ". Will show. Parking/Access • Wheel stops must be 3'/2" from the front end of the stall when adjacent to landscape areas per Section 21- 56.02(0) of the Land Development Code (LDC). Add dimensions to the site plan. Will show. Landscaping • 183 shrubs are required for this project, additional shrubs must be shown on revised landscape plans. Will show. • Dwarf Juniper is not classified as a shrub. Revise landscape plans accordingly. Will change plan. • 13 trees are required for this project. Indicate the dimensions of the Cabbage Palms on the landscape plans. Will add 1 tree and show dimensions on plan. • Add a planting schedule on landscape plans indicating the number of trees and shrubs and their respective dimensions. Will show. • Show reclaimed water lines on the landscape plans. Will show. Per Terry — can punch backflow preventer under road. Building Department • The construction is type IV unprotected and unsprinkled. Will show. • Engineered drawings must be submitted for the steel building for permitting. Will provide. • If the building is to be partitioned in the futur3e, a second bathroom will be required. Suggest installation of underground sewer piping prior to the placement of concrete. Will show. • Approved backflow devices shall be installed on water lines. Is shown on plan. • Construction drawings shall comply with all applicable codes. O. K. Environmental Services • The backflow preventer must be a reduced pressure device appearing on the approved list at the Department of Environmental Services Administration Office. Will add note. • If refuse service for the site is to be provided by the City of Edgewater, trash receptacles must be place curbside by 7:00 a.m. on each scheduled pick -up day. Refuse service ewill be curbside, will show on plan. Fire Department • The required fire flow for this project is 750 gallons per minute. Will add note. Legal Department • No Comments. City En ig neer • 6" PVC pipes must have inverts shown on the plans. Will add note. • Filter cloth to be amoco 4545. O.K.