11-03-2004 - Pinehurst PUDPinehurst PUD
TRC Comments
1 Review 10 -04
TRC Meeting 11 -03 -04
IN ATTENDANCE:
Darren Lear — Chief Planner
Jill Danigel — Fire Marshall
Terry Wadsworth — Dir., Environmental Svs.
Tracey Barlow — Fire Chief
Dennis Fischer — Building Official
Brenda Johnson — Dep Dir, En. Svs
Danny Johns, PE
Pat Drosten, Planning Technician
Ken Hooper — City Manager
Jim Scott
PLANNING DEPARTMENT
1. Show location of any specimen and /or historic trees, per Section 21- 163.02(b) of the City of
Edgewater Land Development Code.
OK
2. Show names of adjoining property owners and existing land uses on vicinity map, per Section
21.163.03(a).
OK
3. Per Section 21- 163.03(1) provide a tree survey that indicates and identifies all trees twelve inches
(12 "), or greater, DBH and identifies which trees are proposed to be removed.
OK
4. Per Section 21- 163.03(n), provide a preliminary landscape plan for common areas.
OK — Will note areas to remain natural.
5. Per Section 21- 51.02(1), - The developer shall obtain approved plans from appropriate electrical
utility provider for street light design. All new developments shall be required to create a
streetlight assessment district to fund installation and operation /maintenance expenses. The
streetlight district will be under the control of the homeowner association. Streetlights shall be
generally provided at all intersections, and at intervals along each street of between 300 and 400
feet. Also please provide a streetlight on Canal Drive.
OK
Provide copies or letters of exemption for the following permits (if applicable):
a. St. Johns River Water Management District - Submitted
b. Army Corps of Engineers
c. Florida Department of Transportation
d. Florida Fish and Wildlife Commission
e. Department of Health and Rehabilitative Services
f. Department of Environmental Protection
g. Volusia County
OK
OK
OK
OK
Sheet 1, Note 5 — Change Nocatee to Pinehurst
Sheet 1, Note 8 — Delete "or seeded ".
9. Sheet 1, Note 18 — Add "common areas and" after "maintenance of all ".
Pinehurst 1st Review 10 -04
Pinehurst PUD
TRC Comments
1 St Review 10 -04
TRC Meeting 11 -03 -04
10. Sheet 2 — Site Data — Change zoning designation to RPUD.
OK
11. Sheet 2 — Note 3 — Furnish complete sentence.
OK
12. Sheet 2, Note 15 — Add "book 5211, pages 4387-4402".
OK
13. Sheet 3 — adjust note regarding 4: PVC Force Main to read "Tie ", not "Tir ".
OK
14. Provide sketch for connection to utilities along US Highway 1 and utility easement
documentation.
Terry will check possibilities for connection with Mr. Scott.
15. Provide sign details.
OK
16. Adjust City limit lines on vicinity map on sheet 2.
OK
17. Setbacks on plat and Declaration of Covenants and Restrictions are inconsistent with the PUD
Agreement.
OK
18. Per the P.U.D. Agreement, sidewalks are to be located on each side of the street; also provide
sidewalks for lots along Canal Drive.
Sidewalks required on one side along Canal Dr.
19. Legal Description is inconsistent with Title Policy.
OK
20. Add signature line for Clerk of Court on Sheet 2 of the Preliminary Plat.
OK
21. Show sewer connection to Lot 9.
OK
22. Per Section 21- 163.02 - A soil report based on a minimum of one percolation test per ten (10)
acres and one, or more, eight foot (8') deep soil borings at a percolation test site. Please provide.
Provided in drainage calculations.
23. Provide verification from Volusia County that subdivision name and street names are available.
OK
BUILDING DEPARTMENT
1. Indicate all applicable setbacks on plat (e.g. pools, decks, side corner, etc.) and in Declaration of
Covenants and Restrictions, per PUD Agreement.
OK
FIRE DEPARTMENT
1. Fire hydrants shall be flow tested prior to construction to ensure adequate fire protection. The
hydrants shall be painted and identified in accordance with City specifications.
OK
ENVIRONMENTAL SERVICE DEPARTMENT
WATER
1. Water line should be looped around cul -de -sac to prevent the dead end line.
OK
Pinehurst 1 st Review 10 -04 2
Pinehurst PUD
TRC Comments
1st Review 10 -04
TRC Meeting 11 -03 -04
2. Add note that locate wire shall be placed on all water mains.
OK
SEWER
1. Sewer line would be better accessible if placed on street side rather than the rear lot easement.
OK
2. Add note that locate wire shall be placed full length of the force main.
OK
3. Sanitary Note #27 — No fittings shall be PVC. All fittings for the force main shall be epoxy lined
ductile iron pipe.
OK
4. Force main design needs to be shown to the tie -in proposed at U.S. 41. Detail should also be shown
for this tie -in.
OK
5. Detail area around lift station should be shown with landscaping and fencing.
OK
6. 'A Turn gate valve with a by -pass tee fitting should be installed on the discharge side of the lift
station.
OK
7. An air release valve should be located near the tie -in at U.S. # 1.
OK
STORMWATER
1. Stormwater calculations review to be done by City Engineer.
OK
2. An NPDES Construction Permit from the Florida Department of Environmental Protection will be
required. Copy of NOI is to be furnished to the Planning Department.
OK
STREETS
1. Canal Road is a County Road; therefore, a County Use Permit will be required for the street
connections, the force main construction and the outfall from the stormwater system.
OK
OTHER
1. Note #5 — Change the name from Nocatee HOA to Pinehurst HOA.
OK
2. Note #8 — All common areas not to be disturbed by house construction shall be sodded.
OK
3. Note #18 —Per the proposed HOA Article of Incorporation, the HOA is responsible for the entire
stormwater system, not just the retention areas.
OK
CITY ENGINEER — Quentin Hampton (David King)
Utilities
1. It is recommended that an alternate sewer design to serve lots 16 -21 from sewer in rights -of -way
be provided, or at least a minimum a wider utility easement be provided.
OK
Pinehurst 1 st Review 10 -04 3
Pinehurst PUD
TRC Comments
1" Review 10 -04
TRC Meeting 11 -03 -04
2. It is recommended to have the proposed lift station and /or manholes located at "edge" of
subdivision and /or deeper to allow for acceptance of offsite flow in the future. This applies to the
north and east "edges ".
OK - Clarified
3. Streetlights per Section 21- 51.02, i, are required.
OK
4. Required separation between proposed force main and existing water main should be shown on
plan sheet.
re
NO
Lift station site should be detailed in the plans and should conform to City Standard Construction
Detail, S -15.
6. Calculations for pump and force main sizing should be provided.
OK
Vehicle/Pedestrian Circulation
1. A copy of the Volusia County Use Permit for the connection to Canal Drive should be provided to the
City.
OK
2. Sidewalks per Section 21 -52.04 are required.
OK
Stormwater Management
1. A copy of the Volusia County Use Permit for the pond outfall in Canal Drive swale should be
provided to the City.
OK
2. A copy of the SJRWMD ERP (permit) should be provided to the City.
OK
Concurrency
1. Applicant should revise Infrastructure Impact Assessment sanitary sewer and solid waste quantities
per Section 21 -135.
OK
Engineer's Estimate
Estimate appears to be in -line /adequate.
OK
Other
1. City should be provided copies of private utility design coordination for telephone, electric, TV cable,
and gas.
OK
BELLSOUTH
BELLSOUTH has adequate facilities to provide service to the above mentioned subdivision.
BELLSOUTH requires a digital copy of the plans which can be e- mailed or a disk mailed to me.
I prefer the e- mailed version.
BELLSOUTH must have 911 addressing for each lot prior to final engineering. I can not release the
Drawings for construction with out the 911 addressing.
Pinehurst 1st Review 10 -04 4
Pinehurst PUD
TRC Comments
1" Review 10 -04
TRC Meeting 11 -03 -04
Thank you in advance for your help.
John Bovee
Phone: 386 - 252 -0818
Cell: 386- 290 -9251
Fax: 386 - 252 -7121
E -Mail: John.Bovee @BELLSOUTH.com
Addr: 900 N Nova Rd
Daytona Beach, Fl 32117
OK
These comments are offered for your consideration and do not constitute an unconditional acceptance of
the project nor do they exempt the developer from having to comply with other City, County, State, or
Federal requirements involved with the project.
Public Hearines for Preliminary Plat approval shall be scheduled at such time as all TRC
comments are addressed.
Sewer /water line easements could be a problem for this site. City and Mr. Scott will look into
alternatives