07-08-2008 - Lo MedicalSP 0807 — Lo Medical Technical Review Committee Comments First submittal — 6/25 TRC date — July 8, 2008 In Attendance: DARREN LEAR, DEVEOPMENT SERVICES DIRECTOR JIL DANIGEL, FIRE MARSHAL TROY TARBOX, APPLICANT ELLY LO, PROPERTY OWNER BREWNDA DEWEES, ENVIRONMENTAL SERVICES INTERIUM DIRECTOR PAT DROSTEN, PLANNING TECHNICIAN Planning Department Landscape 1. Per Section 21 -54.02 [fl Indicate that all disturbed areas shall be sodded. OK 2. Removal of historic trees { Those listed in Section 21 -55.06 that reach 36 inches} must be approved by City Council per Section 21- 55.05. THERE ARE 2 HISTORIC TREES ON SITE, IT MAY BE POSSIBLE TO SAVE ONE (36') BUT ONE (48') WILL REQUIRE REMOVAL. MUST GO BEFORE CITY COUNCIL FOR PERMIT 3. Per Section 21- 55.07, 50% of the existing on site historic and specimen trees must be protected. THIS MA Y NOT BE POSSIBLE, MITIGA TION MA Y BE REQUIRED 4. Fifteen percent of the square footage of any development shall be designated for tree protection per Section 21- 55.08. Indicate compliance on revised plans. No trees may be disturbed in this area. THIS MAYNOT BE POSSIBLE, MITIGATION MAY BE REQUIRED 5. Indicate existing trees to remain on landscape plan for verification of tree number requirements. OK OK 6. A total number of 379 shrubs are required and must be 24' in height @ planting. 7. Landscape plans must indicate from Section 21 -54.02 {c} "All plant materials used in conformance with the requirements of this Section shall be Florida grade #1, as established, and periodically revised by the Florida Department of Agriculture and Consumer Affairs ". OK 8. 56 shrubs and 4 trees are required within the southern buffer area. 9. A class B buffer is required on the western portion of the property. Indicate on revised plans. OK Environmental 1. Provide gopher tortoise survey. PROVIDED BY BCS SP 0807 — Lo Medical Technical Review Committee Comments First submittal — 6/25 TRC date — July 8, 2008 Parking 2. Wheel stops are permitted only under certain storm water conditions. WILL REVISE TO SHOW RAISED SIDEWALK ABUTTING NON HIC STALLS. BALLARDS AREA POSSIBILITY 3. Provide loading berth per Section 21 -57.05 WILL INDICATE STRIPING ON REVISED PLAN Permits Required 1. St. Johns River Water Management District OK 2. Florida Fish and Wildlife Conservation Commission OK 3. NPDES OK — PRIOR TO BUILDING PERMIT 4. FDOT OK General 1. Provide FDOT approval crosswalk markers connecting side walks with in FDOT right of way. OK 2. Revise setback notes sheet C4 setbacks from residential use zoning shall be 50' per Section 21- 50.02. OK 3. Provide proposed signage details. "171 full 4. Indicate compliance to the variance approval conditions placed by Planning and Zoning Board. 5. Revise "Cinty to City" in note #15 under "Water and Sewer Utilities" on page C2. OK Fire - Rescue Department 1. The required fire flow for each building is 1500 gallons per minute. WAYNE WILL CHECK FLOW Legal Department 1. Pursuant to the information contained in the title search, it appears that the title is vested in the name of 418 -420 N. Ridgewood Ave LLC, - you need proof that the Lo's have authority to execute on behalf of the company. PREVIOUSLY ADDRESSED City Engineer (David King — Quentin L. Hampton, Associates, Inc.) 1. All disturbed pervious areas should be sodded and pertinent notes added to site plan. OK SP 0807 — Lo Medical Technical Review Committee Comments First submittal — 6/25 TRC date — July 8, 2008 2. FDOT connection and drainage permits are required, copy of permits should be provided to the City. OK OK 3. A SJRWMD permit is required and should be provided to the City. 4. A FDEP NPDES permit is required, copy of permit should be provided to the City. OK 5. West side screen wall may be desired along entire west property line along east property line adjacent to mobile home park. WALL NOT REQUIRED 6. City may desire wall to be offset from Live Oak Street right of way more than the proposed 1' offset. N/A Department of Environmental Services 1. New 6" fire hydrant and relocating the 6" water main. Proper procedures need to be followed for relocating 6' water main on U.S. 1. a. Isolation of water main for tie in. OK b. Implemented with minimum inconvenience for customers and employees. OK OK OK OK c. Notifying customers of loss of water pressure below 20 psi. d. Boils water notifications issued. e. Water samples in the area affected. f. Boil water notification lifted OK 3. No irrigation water service off of the potable water line. VOLUSIA COUNTY PERMIT REQUIRED 4. Abandon or plug sewer service for he old existing house at 418 North Ridgewood Avenue at Live Oak Street. OK 5. Abandon water service for the old existing house at 418 North Ridgewood Avenue. CITY WILL HANDLE 6. A State of Florida Department of Health permit for water line. FOR RELOCATION - OK SP 0807 — Lo Medical Technical Review Committee Comments First submittal — 6/25 TRC date — July 8, 2008 7. Florida Department of Enviromental Protection NPDES permit will be required prior to Development Order being issued. OK OK OK rf_m OK 8. Under the coordination with County and Utilities section, number seven needs to have my telephone number changed to 424 -2476. 9. Under testing requirements, number five; water lines need to be pressure tested for four hours. 10. Irrigation from potable water is highly discouraged due to cost to the customer. Installing irrigation well is recommended. 11. The City's Land Development Code does not allow wheel stops unless certain storm water conditions exist that warrant their use. Please explain reason or delete from plan. Building Department 1. Tenant separations between units shall be 1 -hour fire rated assemblies. OK 2. Construction Drawings received after October 1, 2008 must comply with the FBC 2007 Code and the NEC 2008. OK 3. Corner unit may need another rear exit due to travel distance. OK APPLICANT WILL SUBMIT ROAD IMPROVEMENT DATA TO DETERMINE IF THEY WILL OFF -SET ROAD IMPACT FEES These comments are intended to comply with City of Edgewater Land Development regulations, FDOT standard specifications and sound engineering practices, and are not meant to be inclusive of all errors or omissions. The engineer of record is solely responsible for technical accuracy, engineering judgment, and quality of work. While every effort is made to assure that projects reviewed by this office comply with all applicable codes and standards, we do not certify or guarantee that they do. It is the responsibility of the applicant to assure compliance with all applicable codes and standards prior to the project being issued a certificate of occupancy.