08-12-2008 - RIX DevelopmentSP-0808 — RIX Development TRC METING MINUTES 8/12/08 IN ATTENDANCE Pat Drosten — Planning Technician Tabitha Russell - Planning Technician Jill Danigel — Fire Marshal Wayne Nichols — Environmental Services Tracey Barlow — Acting City Manager Jeff Rix Jeremy Anderson, Project Engineer Only items in question were addressed. Planning Dept I. Per Sec. 21.52.02, prior to issuance of a building permit, access shall be to an improved roadway. Mr. Barlow discussed the status ofroad improvements. Mr. Rix will provide a cost estimate and the costs will he shared by the effected property owners and the City on a 113, 113, 113 basis (113 accessed to owners on each side of the road and 113 to the City. There are some easement issues that the City is addressing. These issues will not delay development of the subject property as long as the `fair share" amount has been deposited into an escrow account. 2. Indicate building height. (Section 21 OK 3. Indicate Flood Zone information in General Notes OK 4. Wheelstops are only permitted under certain stormwater conditions per Section 21 OK 5. There is a fifty foot (50 setback abutting residential use /zoning (southern boundary line for Phases 2 &3) Will request a variance from this requirement 6. Sidewalks are required for all new development and redevelopment. This requirement may be mitigated via payment into the Pedestrian Circulation Fund at the City's discretion. OK 7. Indicate positive outfall to a public conveyance. OK 8. Per Section 21-57, Table V indicate compliance with required maneuver depth and radius along the north portion of the parking area. OK 9. Site Plan notes indicate the proposed use to be office /warehouse. Provide dimensions for each use for review of compliance with minimum parking space requirements per Section 21-52.04. Parking spaces shall have a depth of 20 feet unless curbed (18' depth with curbing). OK 10. Per Section 21-57.05, one loading berth is required. Please show on plans. OK 11. A total of 324 shrubs are required for this site. Revise planting schedule to indicate minimum of 24" for shrubs. A total of 37 trees are required @ 2.5" diameter measured 6" above the soil line. OK 12. Add note that all disturbed areas are to be sodded, per Section 21-54.03. OK 13. Indicate irrigation plan. OK 14. Per Section 21-54 a Class C landscape buffer is required on the southern property line. Indicate compliance and show planting schedule (NOTE: depending on which option is used, a 6 foot masonry wall may be required). Will request a variance from this requirement 15. Provide a note stating that all disturbed areas shall be sodded. OK 16. Provide detail of the dumpster enclosure. OK 17. Provide note in landscape plans that "All plantings shall be FL Grade #1 or better. OK Building Department 1. Tenant separations between units shall be 2-hour fire rated assemblies. OK 2. Construction drawings received after December 31, 2008 must comply with the FBC 2007 Code and the NED 2008. OK Fire Department 1. The required fire flow for this project is 1500 gallons per minute. This requirement applies to both Phase I and the entire project OK Environmental Services 1. Existing 2" water line needs to remain in use until new installed water line is put into service. OK 2. Existing water service for 201 Park Avenue on North Old County Road need to be tied into new installed water line. OK 3. Need to extend new water line to the edge of northern property line for future growth and tie back into existing 2" water line. OK 4. Tie proposed 1 '/2 water service into water main, not the dedicated fire hydrant line. OK Engineer - David King, P.E. — Quentin L. Hampton Associates, Inc. 1. The plans should include a note stating "All construction shall be in conformance with the City of Edgewater Land Development Code and Standard Construction Details, Latest Version, unless otherwise specifically approved." OK 2. Vicinity Plan should show zoning classification, owners name and existing land uses of adjoining properties (Section 21- 163.03). OK 3. Concurrency determination letter from Development Services Department is required. OK 4. FDEP / VCHD permits for the sewer and water improvements are required. OK 5. If the stabilized area (shell lay-down) is going to be used for equipment / machinery or work vehicles storage an 8' screening wall is required. A statement describing specific use of this area is required per Sec. 21 OK 6. No pavement, driveway or concrete pad should encroach the 5' minimum setback from property line. Dumpster pad should be moved T east to comply. OK 7. Applicant should justify use of exfiltration system as such is to be discouraged per 2153.04,h. we defer this issue to the corresponding regulatory agency SJRWMD. OK 8. A SJRWMD permit is required and should be provided to the City. OK 9. The roof drainage should be routed to the stormwater treatment system. OK 10. Proposed electric service and meter location should be shown on plans as well as other private utilities (phone, gas, cable, etc). OK 11. Proposed exterior illumination plan /design should be provided. OK 12. For site development review purposes, buildings floor plans should be submitted depicting, doorways, any change of level, building height, construction type, elevations, etc. OK 13. Compensating flood plain storage is required since site is located in area with expected 100 year flood elevation of 8.5 as found in the City's Gabordy Canal Basin Study by PEC (see attached). Also, existing storm pipes apparently exist on Old County Road. Staff will email copy ofstudy'to Mr. Anderson 14. A Volusia County Use Permit will be required due to the fact that Park Ave. and the existing storm pipe to be connected to is the County's jurisdiction. OK 15. Additional sewer clean - out should be installed at right-of-way line. OK 16. NPDES permit coverage should be obtained as required. OK 17. Water main should be extended along Old County Road to north end of property. City may desire applicant to construct a 12 inch diameter water main versus a 6 inch main. Wayne wj l get back to Mr. Anderson regarding this issue 18. Thrust blocks are not permitted. Mechanical pipe restraints are to be used. Detail on sheet C3.1 should be removed. OK 19. Details included in plans should be replaced with City standard details. OK Copies of all required permits and supporting information including all revisions to design should be provided to the City.