Loading...
05-14-2002 - Majestic Oaks SubdivisionMajestic Oaks Subdivision TRC MEETING 05/14/02 PLANNING DEPARTMENT • Per Section 21.36.01(a&d), the Developer shall be required to provide a traffic impact analysis. • A DOT Permit will be required for access to U.S. 1. • A SJRWMD Permit will be required prior to final plat approval. • All required utility easements must be shown on revised site plan. • Section 21-60.02(e) states all signs permitted after 2/1/97 shall permanently affix a weather resistant label that includes the date of erection, the permit number, the name of installer and the voltage of any electrical apparatus. • Section 21-163.03(m) requires a tree survey that locates and identifies all trees 12” or greater, DBH identifying those to be removed. • Section 21-163.03(o) requires a street tree plan. • Section 21.169.03(b)(5) requires a “minimum of two points of access shall be provided into each subdivision with 25 lots or more.” The ingress/egress at Glenwood Drive is precluded due to the 5’ planted buffer that surrounds Florida Shores unless the planted buffer area is abandoned. • Label the Southwestern corner (between Lots 92 and 97) as common area and address all applicable requirements. • Section 21-169.04(9)(o) Prior to preliminary plat approval the subdivider shall submit in writing a landscaping plan, including the overall proposed landscaping and treatment of open and common areas. The subdivider shall demonstrate that to the greatest extent practical, existing trees shall be protected and/or new tress planted to establish the maximum percent of lot crown cover. • Revised site plan must show new street names in compliance with Section 21.163.03(b). BUILDING DEPARTMENT • The proposed side set back of five (5’) feet will establish a ten (10’) foot separation between dwellings. The overhangs on each dwelling will be approximately two (2’) feet in length, leaving only six (6’) feet between combustible materials. The building code allows set backs to be less than six (6’) feet with the fire rated exteriors. Masonry walls located at less than ten (10’) feet to a property line shall have two (2) hour fire rating with only twenty (20%) percent openings in the wall per Table 600 of the Florida Building Code 2001 edition. • The five (5’) foot set backs between each dwelling will create problems when installing air conditioning equipment or sidewalks. The storage of boats and recreational vehicles will be in the front yards unless a defined storage lot is provided. • Setbacks should be a combination of fifteen (15’) feet with one side not less than five (5’) feet. This will allow air conditioning equipment installation and the possibility of vehicle or boat storage in the side yard. The side corner setback should be 15 (15’) feet. • The rear exit to Glenwood Drive will create a “short-cut” to Florida Shores. This extra amount of traffic entering and leaving this subdivision will result in numerous complaints from the residences. No traffic light is proposed on U.S. 1, leaving the possibility of serious injury. I would recommend a reinforced sub base with a grass cover instead of a paved roadway for emergency vehicles only. ENVIRONMENTAL SERVICES WATER • The existing 6” water main shown on the plans to be abandoned is currently the only means of providing water availability to the lots east of Majestic Oaks fronting U.S. Highway #1. I am requesting the developer provide an 8” water line along Majestic Oaks Drive to U.S. #1 and to tee the line off so it extends past the entranceway on both sides parallel to U.S. #1 so the City can extend the water line and loop the distribution system with the existing 8” water line on the west side of U.S. #1 at the Medical Arts Building. This will allow the City to service the reference lots on U.S. #1 with water as well as providing an 8” feed to Majestic Oaks which will currently be supplied by two 6” water mains. SEWER • The developer is responsible for upgrading, to City Standards and specifications, the two City lift stations, which will receive flow from this project. • The developer has proposed installing four (4) new sewer laterals on the existing vetrified clay sewer line running along the existing ditch on the east side of the project. I would propose the developer consider replacing the run of line between the existing manholes where the new services are to go with a new PVC sewer main. A large section will need to be wellpointed either way and the PVC pipe would be easier to work with and provide for better system infiltration integrity. STORMWATER • At the northwest area of the project is a ditch, which drains Silver Circle. On page 4 of the plans this area is depicted as remaining natural. There needs to be a positive outfall going to the ditch along Glenwood Drive. • In conversation with Mr. Grant, it has been indicated a revision for the west side drainage area is forthcoming. Staff wishes to review and comment on that new design/configuration as well. • Is it a St. Johns Requirement all the retention ponds are at the same level? If these are to be dry ponds that does not create a problem, but with wet ponds the City has experienced issues with maintainability and mosquito breeding. GENERAL • Attached is a copy of the EASTMENT DEED (ATTACHMENT #1) for the existing water, sewer, and drainage facilities along the eastern boundary of this project. It is unclear at this point if there will be two overlapping easements, or if the one shown on the plans is to become the sole easement, or even if the shown easement is the same as the legal description of the attached easement. Some clarification would be appreciated. The Environmental Service Department reserves the right to add additional requirements to ensure compliance with City, State and Federal codes as well as to safeguard the health and welfare of the general public. PARKS AND RECREATION DEPARTMENT • What is the legal status of 30-foot drainage easement on east property line? Who maintains ditch? • Development Agreement should include that Homeowners Association will be responsible for maintaining and /or operation of landscaped areas at entrance into development, all signage, streetlights and all common areas. Plans should include layout of all signage and streetlights. • Homeowners Association should be responsible for maintenance of all retention and drainage areas. • The Conservation Easement is dedicated to the City. Homeowners Association should be responsible for and all maintenance of area. • Per Caldwell judgment, lots adjoining Silver Ridge Subdivision are to be no less than 150 foot in depth (north-south). Said lots shall include a combined 45-foot buffer with the first 25 feet adjoining Silver Ridge to be a buffer of natural vegetation not included as part of the rear yard and the next 20 feet will be a utility easement, which is to be considered part of the rear yard. It appears that Tract A and Tract D along with Lots 16 and Lots 1 through 7 do not meet this requirement. FIRE DEPARTMENT • No comments at this time POLICE DEPARTMENT • No comments LEGAL DEPARTMENT • No comments CITY ENGINEER • Need road grades and drainage method on the two southern road stubs to Phase 2. Cross road valley gutters are not recommended. • Drainage spread is excessive on Majestic Oaks Drive between Station 11+00 to 12+20. Recommend an additional inlet at Station 11+00 left. • Drainage spread is excessive on Water Oak drive between Station 7+00 and Station 9+50. Ten feet of roadway must be dry. Also, on Bluejack Oak Drive between Stations 0+00 to Station 4+00 is excessive. • Need drainage flow arrows on Diamond Leaf Oak Drive. Also need stationing from Station 3+00 and to the south. • Flow arrow at Station 12+75 on Water Oak Drive needs to be reversed. Also, the flow arrow on Bluejack Oak Drive at Station 5+50 needs to be reversed. • More information is required and should be shown on the plans about the outfall canal system to the east and the existing canal on the west. Critical water elevations in these existing systems are required also. • A permeability Test is required (a Percolation Test does not qualify for this test) • Retention Area(s) must be designated on the plans by volume retained. • Critical water table information must be provided. • The stormwater runoff is not allowed to drain on any adjacent property owners. • All storm inlets must be constructed with 18-inch sump. • Crossroad swales are not permitted. • Need computations on all pipe designs. Written response to these comments are required with submittal of seven (7) sets of revised Site Plans. While every effort is made to assure that projects reviewed by this office comply with all applicable codes and standards, we do not certify or guarantee that they do. It is the responsibility of the applicant to assure compliance with all applicable codes and standards prior to the project being issued a certificate of occupancy. Attachments: Easement Deed