Loading...
Edgewater Commons - Publix - Sealed 02-06-1992 & 02-07-199211 N MOST REMOTE STORAGE AREA. 3000 SO FT MOST REMOTE SALES AREA. 2500 SO FT DREZZAHOHC pL AH drown check date 16 OCT 91 revisions • • -c e* MAMA co W 0= U w F— N = O U ccn co co Qco ui �r W l.L T U Z CD LL •� DY� W�W ~ Z 00 CL w OOw Q U cn F— V) z � 00 Q Q F- O U ry _j w � m � O ry W ry LLJ F- o Q Q z � � Q w W o w 0 � W THE DESIGN INDICATED IN rHS DRAWING AND SPECIFICATION DOES: TO THE BEST OF MY KNOWLEDGE, WORMATION AND BELIEF: COMPLY WITH THE APPLICABLE WNWJM 8Ul.D14G CODES 3 s v job number 4000 sheet number 2"T DROP FROM 2ND FLOOR INSPECTOR'S TEST PIPE pC�04C�C�4�0�1 [PLAN I I,of 1pco it CHECKOUT SPRINKLER LUMINOUS DETAIL CEILING N.T.S. 8' GRV'D ELL 8' FLOW SWITCH \ NOTE -.ALL COUPLINGS BELOW THIS POINT ARE TO BE RIGID COUPLINGS. NOTE: LIST (1) 2' SPLIT CHROME & (1) 2' GALV. WALL PLATES FOR EXTERIOR WALL. 8' MUELLER GRV'D SWING CHECK VALVE 8' RELIABLE MODEL E ALARM VALVE GRV'D W/VARIABLE PRESSURE CLOSED DRAIN TRIM & RETARD CHAMBER 2' ANGLE VALVE i 2' (COJ) 2' GALV. THRU WALL TO 2' GALV. 45 ELL (COJ) 8' OS&Y GATE VALVE i� W/TAMPER SWITCH WELDED FLANGE SPOOL PIECE RED. BAND PBE 8' UG Q 12' AFF WELDED FLANGE i FIRE SPRINKLER RISER DETAIL N.T.S. 0 0 L F. D. CONNECTION (VERIFY LOCATION I W/LOCAL AUTHORITY) �� J ©EN 1211 ___J 4' —J 1 2 1. FIRE MAIN (BY OTHERS) 2. TAPPING VALVE (BY OTHERS) ® 3. VALVE BOX (BY OTHERS) 4. BEND 900 FLANGE/FLANGE 5. DUCTILE IRON PIPE -FLANGE 4 4 6.OS&Y VALVE 7. BACKFLOW PREVENTER (DDC OR RPZ) 8. 3/4'' DETECTOR METER 9. 3/4" BACKFLOW PREVENTER 10. 4'' CONCRETE SLAB 11. 4'' GALVANIZED GUARD POST INSTALLATION INSTALLATION BY OTHERS UNDER THIS CONTRACT drawn check date 16 OCT 91 revisions 4-- FIRE NOTES SPRI KL R E 1. PUBLIX STORE 40M. 2. CEILING CONSTRUCTION IS LAY -IN ACCOUSTICAL TILE. SEE ARCHITECTURAL DRAWINGS FOR SECTIONS, HEIGHT, ETC. LOCATE PENDANTS IN CENTER OF AQCCOUSTICAL TILES. 3. CONSTRUCTION, BLOCK, MERCANTILE OCCUPANCY. USE ORDINARY HAZARD GROUP 1 FOR ALL AREAS EXCEPT STORAGE. v STORAGE AREA SHALL BE ORDINARY HAZARD GROUP 2. • OF7ICE AREA SHALL BE LIGHT HAZARD. c 4. MAIN IS A FIRE MAIN BEHIND PUBLIX PROVIDED BY SITE UTILITIES. 5. WATER SUPPLY PRESSURES, MEASURED OR CALCULATED TO PUBLIX FIRE LINE TAP WITH NO OTHER DEMAND ON FIRE LINE ASSUMED. ■ice SOURCE OF INFORMATION: -AV 0 f �(:0-;71 1N (�v _I � 6, __ ---- -- ----- -- - Io�S W PSI STATIC __ _� _ PSI RESIDUAL AT FLOW OF ____________ GPM 0 W 6. TOTAL AREA COVERED: m 1ST FLOOR - 42438 S.F. U MEZZANINE - 2379 S.F. EZZ W i_ CV 7. HYDRAULIC DESIGN DATA. U 00 SALES AREAS: 0.15 GPM/SQ, FT. FOR MOST REMOTE 2500 SQ. FT. D Q J 0000 tn MAX. 130 SQ. FT. PER SPRINKLER, 160 DEG. F. LL %2 IN. 2-PC. CHROME CELING PENDENT TYPE, K- 4.0 U Z CO STORAGE AREAS: 0.25 GPM/SQ. FT. FOR MOST REMOTE 3000 SQ. FT. x LLMAX. 100 SQ. FT. PER SPRINKLER, 286 DEG. F. 5 r� - "/32 IN. 2-PC. CHROME CEILING PENDENT TYPE, K- 6.1 •�� � � UJ W FREEZER COOLER AREAS: SAME AS STORAGE EXCEPT DRY TYPE 160 DEG. F. F- z PENDENT SPRINKLER HEADS ARE USED 0 O DQ_ It 6L 8. FIRE MAIN SIZE: O O J LLJ 0.15(2500) 375 GPM Q Um 0.25(3000) 750 GPM O.S. HOSE ALLOWANCE 250 GPM - _Q T. s-- mi". Pp_ee-�. 4 FLOW 2i,9 P51 Fcsl p' A•T 1055 CAM, USE 8" FIRE MAIN RISER MAX VELOCITY IN PIPE - 8.78 FPS 9, AREA OF HORIZONTAL RUNS: IN JOISTS AND GIRDER TRUSSES. 8" ABOVE CEILING (NOT TO CONFLICT WITH LIGHT FIXTURES). FIRE SPRINKLER LEGEND BACKFLOW PREVENTOR DETAIL N.T.S. D. H. PUBLIC DOUBLE HYDRANT >_ FIRE DEPARTMENT CONNECTION ® SPRINKLER RISER RECESSED PENDENT TYPE SPRINKLER, 1/2" 160 DEG. F. �-�-- DRY PENDENT TYPE SPRINKLER, 1/2" 160 DEG. F. wp PUBLIC WATER MAIN (SIZE AS INDICATED) UPRIGHT TYPE SPRINKLER, 1'12" 160 DEG. F. PENDENT TYPE SPRINKLER, 1% " 286 DEG. F. >__ SIDEWALL TYPE SPRINKLER, '12" 160 DEG. F. SPRINKL E VALVE EL 7'-Ir MAX. 1/2' SMOOTH BORE BRASS OUTLET FLOOR ONSIPIECTO[No a TIE 307 PODCE c%) z0 o� � o cl:� Q o O o u ry I w � m ry O ry W ry � F- o Q Q z 3: � Q w 0 W o � v) w 0 D W THE DESIGN INDICATED IN THIS DRAWING AND SPECIFICATION DUES: TO THE BEST OF MY KNOWLEDGE, INFORMATION AND BELIEF; COMPLY WITH THE APPLICABLE M NISI M BUILDING CODES 0 o 6 c 3 O L 3 job monber [F 0fr31E 1p R (0 V 19= c V (0 H D[P=VAOLS sheet number 'Qp [F 1p a of 2