Loading...
India Palm Drive Water Line Installation - 04-14-19970• NO. I DATE BACTERIOLOGICAL TESTING POINT #1 6" TAPPING SLEEVE & VALVE INDIA EXISTING 6" WATER LINE REVISION DESCRIPTION PROPOSED 6" WATER LINE BY I REV• NO.1 DATE 7' EXIST. 2" WATER LINE PROPOSED 6" VALVE RAW — — REVISION DESCRIPTION PALM BY P- cn EXISTING 6" WATER LINE IN PLACE UNDER ROADWAY SEE PROFILE SHEET 2 p' •\\�\ �: •' ,..'r• � �• \\o 'g Ed p • \ . % ge\ater `` - . ay \ O o � 1 u\ 1 � \�\ ,,\\ t�-.ice.`-`� �r� � •\. °\\\ c �` ��' ON Nvp 32 \ I I� IL 1� \ A •• \ � `t • y • 0\\ + o VD \ ea �- T r a l r ar \ \ \ � �,\ •\ �\� .\ E::::.... I P •izi: l r ( " \ r�� ; `��iF (:1; A '� /t Vv A rl 13 LOCATION MAP R/W EXISTING 20' ASPH. PAV'T. TYP.. -,� EXIST. 3" REUSE LINE DRIVE EXIST. 2" WATER LINE co N INSTALLATION PLAN, 1" =40' EXISTING 6" WATER LINE EXIST. 6" VALVE W/CORP. STOP - BACTERIOLOGICAL TESTING POINT #2 cn BL✓ DESIGNED KWF INDIA PALM DRIVE DIMWN BVB ,� cITY of EDGEWATER WATER LINE INSTALLATION CHECKED K"` _ ENGINEERING oA� <�,<�s� s"`�' "° , °` � DEPARTMENT SCALE: AS SHOWN PROJECT N0. I ' W AVrhYMM wI1Njwpa15 Gi 055 IM HPLW fee C 055 fee wmmlw Wrz=r 11 WT Mao." w r 1WICA TMON 90' ffw AIMP fet 4011 xw WfalK. 8 5M tff 1w. neffAar ro fowu a5a 1. CONCRETE THRUST BLOCKS SHALL BE REQUIRED AGAINST UNDISTURBED MATERIAL. WHERE TRENCH WALL HAS BEEN DISTURBED, EXCAVATE ALL LOOSE MATERIAL AND EXTEND � THRUST BLOCK TO UNDISTURBED MATERIAL. 2. ON TEES AND BENDS EXTEND THRUST BLOCK FULL LENGTH OF FITTING. J. 20 MIL POLYETHYLENE SHEET BETWEEN PLUG OF TEE OR CROSS BEFORE POURING CONCRETE THRUST BLOCK. 4. BACKFILL SHALL CONSIST ENTIRELY OF CLEAN SAND & ROCK FRAGMENTS. ANY MUCK ENCOUNTERED SHALL BE REPLACED WITH ACCEPTABLE BACKFILL. 5. ALL FRAME BLOCKING SHALL BE PRESSURE TREATED. THRUST BLOCK DETAILS TRENCH Plugs & Caps Pipe 90' Bend 45' Bend 22 1/2' Bend 11 1/4' Bend Wyes & Tees Did. (Ins) Bearing Area Bearing Area Bearing Area Bearing Area Bearing Area Max. Width Min. Cover Bearing Area Sg. Ft. Sg. Ft. Sg. Ft. Sg. Ft. Sg. Ft. Sq. Ft. 2 0.5 0.5 0.5 0.5 0.5 18" 30" 0.5 3 1.0 1.0 1.0 1.0 1.0 18" JO" 1.0 4 1.2 1.0 1.0 1.0 1.0 18" 30" 1.2 6 2.6 1.4 1.0 1.0 1.0 21 " Joao 2.6 8 4.6 2.5 1.3 1.0 3.3 24" 30" 4.6 10 7. J J. 9 2.0 1.0 5.9 26" 36" 7.3 12 10.0 5.7 2.9 1.5 7.7 28" 36" 10.0 14 14.2 7.7 3.9 2.0 10.0 30" 36" 14.2 16 18.5 10.0 5.6 2.6 13.4 31 " 36" 18.5 18 23.4 12.7 6.5 3.3 16.6 32" 36" 23.4 20 28.8 15.6 8.0 4.7 20.0 33" 36" 28.8 24 41.7 22.3 10.2 5.9 29.0 J6" 36" 41.7 BASED ON 130 PSI PRESSURES AND 2000 PSF SOIL BEARING VALUES 10'-O" MN. lO'-O" MIV. 6" WAMM tWATM I' I Oft AMM INDIA PALM DRIVE WATER LINE INSTALLATION 3" ;l 6" WAlffM I AM: I W/V rAW Ml15/NAD W Kiffk f FPV55W. rffFWWL5 Mr. i Of AM 15ffmcamcm 3. GA�f�ill�ll�il�Nr��a lO'-O" �iIGII� a� WMpI'AWra w#al5tt55#wl8"6r JW15 w1W lO' GF WAVMNV. 9. GIiCfumvpff mraiwiurvacavaeff Ar"a 1: PtA V s MOFU-M MR s ff0t LTG 005i%6 wro5c" GENERAL NOTES: 1. WATER LINE SHALL BE INSTALLED USING PVC C900. 2. WHERE THE WATER MAIN CROSSES THE SEWER MAIN, THE WATER MAIN SHALL BE AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER PIPE & SHALL BE LOCATED AT LEAST 10 FEET HORIZONTALLY FROM PIPES CARRYING RAW WASTEWATER. WHERE THESE MINIMUM SEPARATIONS CANNOT BE MAINTAINED THE SEWAGE MAIN SHALL BE ENCASED IN CONCRETE. 3. PROVIDE MINIMUM OF 30" PIPE COVER. WHERE MINIMUM OF COVER CANNOT BE MAINTAINED THE WATER LINE SHALL BE ENCASED IN CONCRETE. 4. BEFORE BEING PLACED IN SERVICE, ALL NEW WATER MAINS SHALL BE CHLORINATED IN ACCORDANCE WITH THE PROCEDURES OUTLINE IN AWWA C-651 "STANDARD PROCEDURE FOR DISINFECTING WATER MAINS' . 5. ALL PIPE SECTIONS TO BE PRESSURE TESTED SHALL BE SUBJECTED TO A HYDROSTATIC PRESSURE OF 150 PSI. THE DURATION OF EACH PRESSURE TEST SHALL BE FOR A PERIOD OF 2 HOURS. IF DURING THE TEST THE INTEGRITY OF THE TESTED LINE IS IN QUESTION, THE CITY MAY REQUIRE A 6 HOUR PRESSURE TEST. THE BASIC PROVISIONS OF AWWA C-600 SHALL BE APPLICABLE. 6. AFTER COMPLETION OF THE PRESSURE TEST, A LEAKAGE TEST SHALL BE CONDUCTED TO DETERMINE THE QUANTITY OF WATER LOST BY LEAKAGE UNDER THE SPECIFIED TEST PRESSURE. APPLICABLE PROVISIONS OF AWWA C600 SHALL APPLY. ALLOWABLE LEAKAGE IN GALLONS PER HOUR FOR PIPELINE SHALL NOT BE GREATER THAN THAT DETERMINED BY THE FORMULA: L= SD (P)1/2 133,200 L= ALLOWABLE LEAKAGE IN GALLONS PER HOUR. S= LENGTH OF PIPE TESTED, IN FEET. D= NOMINAL DIAMETER OF THE PIPE IN INCHES. P= AVERAGE TEST PRESSURE DURING LEAKAGE TEST IN POUNDS PER SQUARE INCH GAUGE. DESIGNED I B�F DRAWN I eve CHECKED I KWF DATE.• 4114197 SHEET NO. 2 OF 2 CITY OF EDGEWATER ENGINEERING DEPARTMENT NO. I DATE REVISION DESCRIPTION BY IREV. NO.1 DATE REVISION DESCRIPTION SCALE: NONE PROJECT NO.