Miscellaneous Documents CITY OF EDGEWATER
PLANNING DEPARTMENT
139 East Park Avenue, Edgewater,Florida 32132
386-424-2412
Received
SITE PLAN REVIEW—APPLICATION NOV 2 2 pno6
**ALL ENGINEERING REVIEW COSTS SHALL BE City of Edgewater
REIMBURSED BY APPLICANT/OWNER Flanging&Development
OFFICE USE ONLY
DATE APPLICATION RECEIVED: CASE NO. SPO-14.
FEE (Minor-Staff review only)' $1.500.00
(Major-P&Z/Council review) $2,000
APPLICANT NAME: oirk e ('.kotAkAckn )
MAILING ADDRESS:1 Oa (\5 go\ ' k V-. 9Ark C.01Yoic
PHONE NUMBERS: WORIC:scaik.GIND-4‘11 HOME;
FAX NUMBER: - CVO tj431cc
ENGNEERCat M. *via FL LICENSE# 61,1410
MAILING ADDRESS Le.CUAX1% (4),Ahn (pack ct,
PlloNE:36ko-i.mo q5s
ARCHITECT: FL LICENSE#
MAILIN G ADDRESS:
PHONE:
LANDSCAPE ARCHITECT: ()NV at ?=.1..ChiA" FL LICENSE#CCZO,Actc‘
MAILING ADDRESS:
PHONE:
APPLICANT'S INTEREST IN SUBJECT PROPERTY?MX(106(n, Wit*Q.C) Earlaker
WXIMDel LAZ
OWNER'S NAME (if different from applicant) e ÔDQVkX tAarbof
MAILING ADDREss!n ukrIV.-isr", a NI k-kse,V... kAgy\ Cosa. VX., 3.DAai
site plan plan review-application - 1
rev 6-06
V
PROJECT STREET ADDRESS OR LOCATION: Lv6 kAI-9
DESCRIPTION OF PROJECT:411 U5reax\kVACAMOMMkinq COMA 1.001000 6ftyPt.
t) C_DiAtAwdok
LEGAL DESCRIPTION:N (06 jff O Gat(v ‘44-6°Iacto VI* OV Gat 22 AS5?-
5 6■A'S %.\&A/c { ( AM I mb% ■52.44 ?Alzi o
C3N 1-0-c 442
TOTAL ACREAGE: . a\,
PARCEL#(S) Ot-00-01,00
%OF LOT AREA TO BE COVERED BY 13UILDWG(S)
TOTAL IMPERVIOUS AREA ! 31 00re
EXISTING ZONING:P.. Pus) EXISTING USE:
FUTURE LAND USE MAP DESIGNATION:VVYA kkoe, ‘).)\"\AA CIAW4 Oki b el 04ff
Pursuant to Chapter 286,P.S., if an individual decides to appeal any decision made with respect
to any matter considered at a meeting Or hearing,that individual will need a record of the
proceedings and will need to insure that a verbatim record of the proceeding is made. The City
does not prepare or proVide.such record. ,
PLEASE SUBMIT YOUR APPLICATION ACCURATELY WITH A COMPLETED,
CHECKLIST AND ALL REQUIRED ATTACHMENTS. SUBMISSION OF AN
INCOMPLETE APPLICATION WILL DELAY PUBLIC HEARINGS
Site Plan Review applicants must resubmit plans in response to TRC (Technical Review
Committee) comments within.30-days of the TRC meeting or comments being provided to
the a.pplicant. Failure to meet the resubmission deadlines shall require the applicant to file
a new application 'including the appropriate review fees.
I have read and agree to the terms and conditions set forth in this application.
SIGNATURE OF OWNER: /
,v1
SIGNATURE OF APPLICANT: DATE
site plan review-application -2—
rev'6-06
THE CITY OF EDGEWATER
NOTARIZED AUTETORMATION Or QWNER
J./We tro 196'4- E. IV irk_VIA'HQ ILI . aS the sole or
(owner's name)
joint fee simple title bolder(s)of the property described as:
Arc.* -/S ot- co - 0/oo
(legal description or parcel number)
authorize Akoc, 4* (Drtiv, ctx, to act as my
„
agent to seek a Sick9/ yvm PrtroNJA on the
(type of request)
above referenced property.
Cgig■i,14<
Owner's Signature Owner's Signature
STATE OF FLORIDA •
COUNTY OF X467,6) _
The foregoing ilistiitnent waS acknowledged before Me on this 0014-e26/(ROCI )(date)by
'?/ +E. e IL 77C- (name of person acknowledging), who is
personallzknown to me or who has produce as
(type of T).)
identification and who did not take and oath
, I*4/11
/9.
1„444_467---.2
NOTARY PIA3LIC—STATE OF FLORIDA
IllgoNsILINgInt;12001643
s-Avotnk, ge\i-i-t3v1k
,-0+1.,sr EXPIRES:July 26,2009
1400-3-NOTARY • "'otar),Disc-cent Assoc.Co. NAME OF NOTARY—TYPED OR PRINTED
11-3,;?0 t3
COMMISSION# I 26) 020C site plan review-application 3—
rev 6-06
SITE PLAN CHECKLIST
Site plan requirements:
4 A completed copy of this checklist
Ten (10)completed(folded) sets of blue lints at time of submittal.
Two (2) sets Of the ten (10) sets to be signed and sealed by an engineer or
I architect registered in the State of Florida,
25-year Ownership and Encumbrance Report dated less than six(6)
months or Title Insurance Policy dated less than six (6)months or Title
/ Report dated less than six (6)months, froth a Title CoMpany.
Stormwater application, and five(5) sets of drainage calculations'signed
/ and and sealed by an engineer registered in the State of Florida
/
7 _
Y Transportation impact study(if applicable)
/ .
Environmental impact study.
Four (4) sets of surveys certified by a Florida licensed and insured PLS
within one (1) year of the filing of the application as reflecting all
,i improvements and conditions on the property*
Four(4) set of Landscape plans.
Three (3) sets of As-Built Site Plans (prior to CO.).
One (1)original estimated flow requirement for water and sewer usage
certified by a Licensed Engineer.
_IL Condo Association documents and by-laws(if applicable).
V/ 1, Detailed location map including the relation of the project site to major streetS,
driveways,existing utilities, and major physical features of the surrounding area.
2. .. ., , .
Topographic information of the existing project site,which shall include, at a
minimum: the project boundaries, existing above ground improvements, a north
arrow, a scale indicator, one-foot contour Imes which extend at least fifty(50)feet
beyond the project in all directions,benchmark information(MVP) and
a: Acreage certification of all land above the elevation of Mean High Water
(MHW) line.
b, The Mean High Water line, if applicable.
c. The location dal submerged lands, if applicable.
/3. The four(4) sets of current survey prepared, signed and sealed by a Professional
Land Surveyor(PLS)licensed and insured in the State of Florida, showing the
followMr,property lines,right-Of-Way, existing trees, easements, streets,
railroads,utility lines, stortriviater iinprovernentt, ditches, culverts,water bodies,
bridge,buildings, bulkheads and bulkhead lines,fuel storage tanks,and other
similar features on the site:A current survey means one that was prepared
specifically for the site plan application and reflects the present conditions found
On the property. The,survey shall be submitted on sheet size twe nty-four(24)by
site plan review-application -4—
rev 6-06
thirty-six(36)inches embossed by the PLS and shall identify any discrepandies
between field dimensions and platted dimensions.
• /4.
Landscape Plans OP include planting schedule) showing existing and proposed
plant list,number,types and sizes in diameter of trees to be retained/removed/
planted. Numbers,types and sizes of shrubs.
Calculations for New Volusia County WaterWiae Ordinance; including Total
Pervious Area;Micro Irrigation Zone; Medium Irrigation Zone, and High
Irrigation Zone.
6. IclentifidatiOn of legal positive outfall with the name of the adjacent propeity'
Miler receiving storm Water discharge, if applicable. Show outfall to public
conveyance.
7.
The boundaries of the'one hundred (100)year floodplain areas,wetland's,
watercourses,ponds,wooded areas and other slit-filar conditions affecting the site.
Drainage.Basin or watershed boundaries identifying locations of the routes of off-
site waters onto,through, or around the project.
V/ 5. A development schedule indicating the approXimate date construction of the
development or stages of the development can be expected to begin and be
completed.
1/ 10. Preliminary Floor Plans(not constructiOn)
VIL A statement explaining any known property boundary conflicts or disputes.
Proposed Development Activity and Design
Detail sheets shall be submitted on a sheet size twenty-four(24)by thirty-Six(36) inches and at a
scale no smaller than one (1) inch equals fifty(50) feet, all dimensions in decimals. For large
projects, a smaller scale generalized plot plan may be submitted as a cover sheet to the details
sheet. Detail Sheets shall include the following information:
11, The location of the property by lot number,block number, and street address.
2. The boundary lines and thefl dimensions of the property, existing subdivision
easeinents,roadways,rail lines, and public right-of-way.
13. The location, dinVrisions,height and uses of all buildings and StnictUres; the exact
number of, and type of any dwelling units; and the architectural elevations of all
buildings and structures including proposed floor plan.
site plan review-application ,5—
rev 6-06
The identification of the maximum buildable area of each lot or parcel within the
proposed develdpinent.
15. The location and dimension 0/pa*ing and loading areas-
The location and size of existing and proposed potable water lines, wastewater
lines,reclaimed water lines,lift statiens,Meter and fire hydrants.
The locations of existing and proposed easements for utility systems, including
sewage facilities and water supply facilities, electric, gas, cable TN., and
telephone lines.
18. The location of all stormwater management areas and drainage improvementS:
9. The existing and proposed traffic circulation system and any other transportation
itnprovements.
/10. The location and size of all areas to be conveyed, dedicated or reserved as
common open space, parks, recreational areas, rights-of-way and other public
uses.
/11. The pedestrian cirdulation system, including its interrelationship with the vehicle
circulation system..
/12. Proposed irrigation system and landscaping, including types, location and
quantity of all trees, plants or materials, and the location of fences or screen
planting,
N/13. The location, size; and arrangement of all existing or proposed signs or lighting.
114. Boundaries depicting Construction phases, if applicable:
115, The approximate location and dimension of all proposed lots and all yard
requirements; if applicable.
/16, A transportation impact study and environmental impact report,if applicable,
17. The location of all driveways,public streets and private drives within 500 feet of
the development, along any private,or public sleet that will serve the project.
48. The location of solid waste collection areas, thimpstet pads and enclosures:
••J 19, Any other information deemed necessary by the Technical Review Committee
(TRC) for the-masonable review of the project.
site plan review-application -6—
rev 6-06
20. St Johns River Water Martagertiont District permit will be required prier to a
building permit being issued for all
a, Conamprcial projects
b. Multi-family projects if ten (10) or more and/or two (2) acres of impervious
area.
\ 21. Florida.Department of EnvirenpaeritaI Protection—I\IPDES Permit for all projects
/
exceeding one(1)acre(Effective May 1,2003).
,---,
site plan rOview-application -7—
rev 6-06
CITY OF EDGEWATER.
AGREEMENT FOR CONSULTANT, LEGAL, ADVERTISING
COSTS & ON-SITE INSPECTIONS
The City of Edgewater contracts for engineering, einill'017172eiltal, planning consultant and legal
services relating to review of development projects. Engineering, environmental, planning
consultant and legal fees associated with planning,zoning or development activities are required
to be paid by the owner/applicant.
Engineering review, environmental review, planning consultant, legal and required ailvertising
costs shall be paid prior to the iswance of a Development Order, Engineering fees for final
approval shall be paid prior to the issuance of a Certificate of Occupancy.
Owner/applicant is required to immediately pay all associated fees upon receipt of each invoice.
The owner/applicant does hereby acknowledge that on-site inspections by City staff, consultants,
elected and appointed officials are permitted on said property.
Own /
er/Applicant Signature ate
site plan review-application -8—
rev 6-06
1
0,1c>/)
1. RESIGN GROUP, INC. 7 2006
cites tl aitiy rvt
Civil Engineering • Land Planning • Permitting • Construction AdministWiffOrilerttSGMCGZ
VIA OVERNIGHT DELIVERY
November 21, 2006
City of Edgewater
Utility Department
104 N. Riverside Drive
Edgewater,FL. 32132
Re: Edgewater Harbor
ADG06034
To whom it may concern:
The total sanitary sewer&water usage projected for Edgewater Harbor is
114,000 gallons per day. This usage was based on a total of 416 residential units,
100,000 sq. ft. of commercial retail space and the following criteria of 250 gallons per
day per unit for the residential portion of the site and 10 gallons per day per 100 sq. ft.
associated with the commercial site.
Thank you for your assistance and should you have any questions or require any
additional information,please feel free to call me anytime.
Sincerely,
Atlas Design Grout .Inc.
"urt M.Wimpe r
As President
Florida P.E. : `6447
CMW/jms
06034032
Enclosures
cc: Jeffery L.Mason.,E.I.
Bobbie Jo Manning !
File
Phone: 386.446.8288 • Fax: 386.446.8277
50 Leanni Way, Suite B4 • Palm Coast, FL 32137
www.atlasdg.com
LETTER OF TRANSMITTAL
•
Facilities services
NEW CONSTRUCTION&INSPECTIONS DEPARTMENT
School Board of Volusia County
To Date — School — Project
Edgewater.Fire Marshall January 4, 2007
Jill Danigel Edgewater Public
Hood Suppression
The Following is/are attached:
Copies Description
1 ea Plans and Specs
•
Document(s) Transmitted:
X For Approval Approved as submitted For correction
For your use/ information Approved as noted As requested
For Review/comment Other
FOR FIELD USE
Remarks - Please respond by email —thank you!
Signed: , F ./r_
Kare Hood khood@volusia.k12.fl.us
4750 Olson Drive, Daytona Beach, FL 32724
(386)947 8786 X50808
- q :a CITY OF EDGEWATER
9 4, Titi, PLANNING DEPARTMENT
� 139 E.PARK AVENUE
P.O.BOX 100
s-r#. Edgewater FL 32132-0100
(386)424-2412
(3861424-2439-FAX
LETTER OF TRANSMITTAL
TO: Utilities(Terry.and Brenda),Legal,Engineer,Fire-Rescue,Building,City Manager
DATE:March 8,2007
RE: SP 0704—Edgewater Harbor
WE ARE SENDING YOU ❑Attached ❑ Under separate cover via. the following items:
❑ LETTER(S) ❑ REPORT(S) 0 PLANS
❑ PRINT(S) Q DOCUMENT(S) ❑ OTHER
1
COPIES DESCRIPTION
Building/Fire—Application,site plan
DOES—Application,site plan,landscape plans,stormwater calcs,environmental study,water/sewer usage
report,lift station calculations 1 &2(Terry.—share 2 with Brenda),surveys(Terry—share with Brenda)
QH—Application,landscape plans,site plan,lift station 1,&2 calculations,stormwater calculations,
surveys,environmental study,water/sewer usage report
City Manager—Application,site plan,landscape plan,lift station 1 calculations,stormwater calcs,
environmental study,water/sewer usage report
Legal—Application,site plan,bylaws,articles of incorporation,surveys,title work,environmental study,
water/sewer usage report
THESE ARE TRANSMITTED as checked below:
❑ For approval ❑ For your information ❑ Resubmit copies for approval
❑ For your use ❑ Per our conversation ❑ Submit copies for approval
❑ As requested ❑ Return as noted ❑ Return corrected prints
El For review and comment ❑ Other
REMARKS Please review the documents provided and return any comments to me by March 29,2007. The TRC for this project
will be scheduled at a later date.
COPY TO SIGNED Jill Danigel
L